遇见数据集

Hybrid architectures for molecular polaritonics

收藏
DataCite Commons2024-05-26 更新2024-08-19 收录
官方服务:

资源简介:

Dataset “Coupled_metasurface”: Contains the frequency and coated/uncoated metasurface transmission data which is shown in Fig. 3. • Frequency is given in terahertz (THz) • The transmission is calculated from the fast Fourier transform of the THz time-domain spectroscopy (THz-TDS) measurements • The frequency/transmission is not cut to the bounds of the measurement noise floor which is roughly from 0.5-2.5 THz Dataset “Planar_mirror_cavity”: Contains the transmission map data of the standard Fabry-Perot cavity architecture which is shown in Fig. 4(a). • Frequency is given in THz • The transmission is calculated from the fast Fourier transform of the THz time-domain spectroscopy (THz-TDS) measurements • The frequency/transmission is not cut to the bounds of the measurement noise floor which is roughly from 0.5-2.5 THz • The transmission datasets are copied into columns in order of increasing cavity spacing (C-AA) • The relative cavity spacing is provided in column B Dataset “Hybrid_cavity_1”: Contains the transmission map data of the first hybrid cavity architecture which is presented in Fig. 4(b). • Frequency is given in THz • The transmission is calculated from the fast Fourier transform of the THz time-domain spectroscopy (THz-TDS) measurements • The frequency/transmission is not cut to the bounds of the measurement noise floor which is roughly from 0.5-2.5 THz • The transmission datasets are copied into columns in order of increasing cavity spacing (C-R) • The relative cavity spacing is provided in column B Dataset “Hybrid_cavity_2”: Contains the transmission map data of the second hybrid cavity architecture which is presented in Fig. 4(c). • Frequency is given in THz • The transmission is calculated from the fast Fourier transform of the THz time-domain spectroscopy (THz-TDS) measurements • The frequency/transmission is not cut to the bounds of the measurement noise floor which is roughly from 0.5-2.5 THz • The transmission datasets are copied into columns in order of increasing cavity spacing (C-Z) • The relative cavity spacing is provided in column B Dataset “Empty_hybrid_cavity”: Contains the transmission map data for the unfilled hybrid cavity architectured which is shown in Fig. S6(b) of the supplementary information. • Frequency is given in THz • The transmission is calculated from the fast Fourier transform of the THz time-domain spectroscopy (THz-TDS) measurements • The frequency/transmission is not cut to the bounds of the measurement noise floor which is roughly from 0.5-2.5 THz • The transmission datasets are copied into columns in order of increasing cavity spacing (C-P) • The relative cavity spacing is provided in column B

提供机构:
figshare
创建时间:
2024-03-15
二维码
社区交流群
二维码
科研交流群
商业服务