One dimensional compression and rebound test results for Rhine sand with an initial density of e = 0.6.
收藏NIAID Data Ecosystem2026-03-08 收录
数据链接:
官方服务:
资源简介:
Initial loading was conducted towards a value of 200 kPa followed by an unloading-reloading path down to 25 kPa. Initial loading was then continued towards a value of 800 kPa.
创建时间:
2013-10-30